Planning Local Extract Ventilation Testing Across Multiple Sites

Coordinating local extract ventilation testing across multiple sites means accounting for different examination deadlines, production schedules and access requirements. A visit that suits one location may clash with production at another, particularly when a process needs to run during part of the examination.

UK guidance refers to these systems as local exhaust ventilation (LEV). Under COSHH, most systems used to control exposure to hazardous substances require a thorough examination and test at least every 14 months, with shorter intervals for certain processes. Each system therefore needs an accurate due date.

An LEV examination can raise questions for both maintenance and health and safety teams, particularly when findings need action at more than one location. Our occupational hygiene specialists carry out thorough examination and testing and provide reports to help the people responsible understand the results and agree the next steps.

How Often Must LEV Systems Be Examined and Tested?

Most local extract ventilation systems used to control exposure to hazardous substances must undergo a thorough examination and test at least every 14 months under COSHH Regulation 9. Certain processes listed in Schedule 4 require shorter intervals of one or six months. Each system therefore needs its own examination date, even when testing is coordinated across several sites.

Where wear or contamination is likely to affect performance before the next examination, a shorter interval may be appropriate. Changes to a process or extraction arrangement can also prompt a review of control performance without waiting for the scheduled visit. Routine checks and maintenance must continue between examinations. Employers must also retain records of thorough examinations and testing, including repairs carried out as a result, for at least five years. Our guide to how often local extract ventilation should be tested explains the intervals in more detail.

How Can You Coordinate LEV Testing Across Multiple Sites?

A shared register of local extract ventilation systems helps managers oversee equipment operating under different conditions. It can identify each system and the process it serves, record the last examination and next due date, and show outstanding defects. Site-specific commissioning information and a named contact make the record useful to the people arranging the examination.

Those details then inform the timetable. Site contacts can agree access windows with their production and maintenance teams, while the person overseeing the programme checks that each date falls within the permitted interval. If one visit needs rearranging, the effect on that system’s deadline can be assessed without changing every site’s plan. Keep completed examinations separate from repairs and follow-up checks so unresolved defects remain visible.

Our qualified occupational hygienists use performance measurements and qualitative assessments to evaluate how effectively each LEV system controls contaminants. Through our LEV thorough examination and testing service, we compare findings with available system specifications and relevant HSG258 criteria. Our reports help your safety and maintenance teams understand where performance needs attention and what corrective work may be necessary.

Can LEV Testing Be Carried Out During Winter Shutdowns?

Local extract ventilation testing during winter shutdowns is sometimes easier to organise because the equipment is more accessible. Even so, access does not guarantee suitable conditions for a full examination. Some performance checks require the LEV, and sometimes the process it serves, to be running so the examiner can assess contaminant control.

Agree those conditions before reserving a shutdown slot. Maintenance teams can use quieter periods to review records, inspect accessible components and complete planned work. Any examinations requiring normal operating conditions should be arranged in time to meet the system’s deadline. This avoids relying on a visit that cannot provide all the required performance information.

What Do Sites Need to Prepare Before LEV Testing?

Previous examination reports, the LEV logbook and commissioning or design information help the examiner establish what performance the system was intended to achieve. Site contacts should flag changes to materials or work methods, modifications to hoods or ductwork, and repairs completed since the last examination. Each change may affect how effectively contaminants are captured.

When production changes at one site, the people responsible for local extract ventilation records across the business may not hear about it straight away. A workstation may be moved or a new material introduced after the last examination, leaving an extraction system operating under conditions not reflected in its earlier performance information. Significant changes to the process, workplace layout or extraction equipment should prompt a competent review. HSG258 advises recommissioning when changes affect the process, layout or LEV installation, so the system can be checked against the required performance standards without waiting for its next routine examination.

Access to the relevant parts of the system also needs to be arranged safely, including any test points and equipment needed for the assessment. If the original commissioning report or design information is unavailable, let the examiner know before the visit. Other suitable performance information may help establish a benchmark, although additional commissioning work may be needed where reliable information is missing. The examiner should explain any limitations so the responsible team understands how the system’s performance has been assessed.

What Should You Do If an LEV System Fails Its Test?

If a local extract ventilation system fails its examination, the employer should respond according to the risk identified in the report. Serious failures that leave workers inadequately protected may require immediate precautions or stopping the affected activity until effective controls are restored. Less serious findings may be addressed through planned maintenance, provided workers remain adequately protected.

Make sure operators and maintenance teams understand what the report identifies. Assign responsibility for the corrective work and arrange for a competent person to confirm that adequate performance has been restored before the issue is closed. Recording a repair as complete is useful for tracking progress, but it is not proof that the system is controlling exposure effectively.

Comparing results between sites also calls for care. A welding extraction hood and a dust collection system serving machining may have different performance requirements, so the same airflow reading cannot automatically be taken as evidence of equivalent control. Consider the operating conditions recorded during each examination, the benchmark used and the examiner’s findings before deciding which defects need attention first. A system that still meets an earlier performance benchmark may nevertheless need review if the process it serves has changed.

Reports from different sites may also show recurring problems, such as damaged hoods or blocked filters. Each finding needs to be considered in the context of its process, but patterns can help managers identify where operator checks or maintenance arrangements deserve closer attention. If uncertainty remains about employees’ actual exposure during particular tasks, our occupational exposure monitoring can provide additional evidence. It measures worker exposure, while the LEV examination assesses the engineering control.

Keep LEV Examination Dates and Findings in View

If you’re arranging local extract ventilation examinations across several sites for 2027, our team can help you establish what each test needs to cover and which operating conditions will be required. Contact us with details of your systems and upcoming deadlines so we can discuss appropriate testing arrangements before you finalise site schedules.